2-8 Zones ⢠En54 Parts 2 & 4 Compliant Fully compliant with EN54 parts 2 and 4, C-TECâS CFP conventional fire alarm panel offers an array of user and installer friendly features. Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4, and 8 zone versions are available, each featuring four conventional sounder […]
READ MORE »Posts in category Conventional Fire Alarms
AD- 101 Manual Call Point (MS)
The Manual Call Point is tough, durable & highly visible. Alarm LED/s is provided inside the Call Point to indicate the Alarm condition. Key Features Available for flush or Surface Mounting. Suitable for majority of conventional Fire Alarm System.
READ MORE »AD- 110 Manual Call Point (ABS)
The Manual Call Point is tough, durable & highly visible. Alarm LED is provided inside the Call Point to indicate the Alarm condition. Key Feature Available for flush or Surface Mounting. Suitable for majority of conventional Fire Alarm System. Front protection glass cover Unbreakable glass ABS plastic body
READ MORE »AD -110 MRU / 110 MAU
AD -110 MRU / 110 MAU MANUAL RELEASE UNIT / MANUAL ABORT UNIT Key Features ABS Plastic Body Front Protection Glass Cover Unbreakable Glass No /NC Potential Free Contacts
READ MORE »AD -110 EDR Emergency Door Release
AD -110 EDR Emergency Door Release Key Features ABS Plastic Body Front Protection Glass Cover Unbreakable Glass No /NC Potential Free Contacts
READ MORE »AD-301(MS) Remote Indicating Lamp
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room. Key Features Dual LED Low Current Consumption
READ MORE »AD-301(M) Remote Indicating Lamp
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room. Key Features Dual LED Low Current Consumption
READ MORE »AD-301(MW) Remote Indicating Lamp
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room. Key Features Dual LED Low Current Consumption
READ MORE »AD- 301 Remote Indicating Lamp
The unit is designed to ensure that Alarm Signal can be actually transmitted to all locations. To prevent any missing signal specially for the close room. Key Features Dual LED Low Current Consumption
READ MORE »Sounder Cum Strobe AD- ES F2
The Sounder cum strobe is designed to give the audio & visual indication in case of emergency & fire. Key Features ABS Plastic Body High Glow LED High Sound output / Light Source
READ MORE »Siren Cum Strobe AD -ESF1
The Sounder cum strobe is designed to give the audio & visual indication in case Key Features ABS Plastic Body 3 Selectable Tones High Sound output / Light Source
READ MORE »AD- 502 Sounder ABS
The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. It provides an audio warning which is suitable for place which needs audio indication. Key Features 24 / 12 Volt DC operation High sound output with low current consumption.
READ MORE »AD- 501 Sounder (MS)
The Electronic sounder is designed for use within fire alarm systems, security systems and industrial signaling systems. It provides an audio warning which is suitable for place which needs audio indication. Key Features 24 / 12 Volt DC operation High sound output with low current
READ MORE »AD- 01 Auto Dialer
Totally Microcontroller Based System 2 â Line, 16 â Character LCD With Backlight 128 â Event Memory Stored In Nonvolatile Memory. 6 Telephone Number with Speech. Dialer With 2 Message and 6 Telephone Number Telephone Number Check Facility Date & Time Display on the LCD Screen At All Time (Optional). Keypad Access Code Only After […]
READ MORE »Photo Electric Smoke Detector
The series 100 range of Conventional detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology.The Series 100 detector incorporates a bi-colour LED indicator. The integral LED is blinking Green when the detectorâs status is Normal and turns steady Red when it is in […]
READ MORE »Multi Criteria Photo Electric Smoke/ Detector
The AD 338 â 2HL photoelectric smoke / thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. An alarm signal is only enabled in the detector once the processor is satisfied that an incipient fire […]
READ MORE »Rate of Rise Thermal Detector
The AD 318 â 2L thermal detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest in thermal element technology the detector provides efficient and accurate detection of fire, especially in environments such as bars or kitchens where smoke detectors are inappropriate due to high level of airborne contamination. standard Features Low profile […]
READ MORE »Panels – Conventional Ravel
RE102 2 Zone Panel Instruction Manual Data Sheet RE104 4 Zone Panel Instruction Manual Data Sheet RE2504 4 Zone Panel (UL) Instruction Manual Data Sheet RE2554 4 Zone Panel(UL) Instruction Manual Data Sheet RE2508 8 Zone Panel (UL) Instruction Manual Data Sheet RE2558 8 Zone Panel (UL) Instruction Manual Data Sheet RE700 12-128 Zone Panel […]
READ MORE »Detectors & Devices
RE316S 2L Conventional Optical Smoke Detector(UL) Instruction Manual Data Sheet RE316H 2L Conventional Heat Detector(UL) Instruction Manual Data Sheet RE316SH 2L Conventional Smoke cum Heat Detector (UL) Instruction Manual Data Sheet RE24SS Conventional sounder cum strobe Instruction Manual Data Sheet RE24CS Mini Horn Instruction Manual Data Sheet RE-RI Response Indicators Instruction Manual Data Sheet RE716M […]
READ MORE »